The International Electrotechnical Commission (IEC) is an international organization that develops and publishes standards for electronic and electrical technologies. One of the important standards developed by the IEC is IEC 60512-2-719:1992 (2017), which pertains to "Connectors for electronic equipment - Tests and measurements - Part 2-719: Electrical continuity and contact resistance tests - Test 2a: Contact resistance." This standard provides guidelines for testing and measuring contact resistance in connectors used in electronic equipment. Let's delve deeper into the technical aspects of this standard.
Importance of Contact Resistance Testing
Contact resistance refers to the electrical resistance between mating contacts in a connector. It is essential to measure contact resistance as it directly affects the performance and reliability of electronic equipment. High contact resistance can lead to voltage drops, increased power consumption, and even signal degradation. Therefore, contact resistance testing plays a crucial role in ensuring the proper functioning of connectors and minimizing the risk of failures or malfunctions.
Test Methods and Procedures
IEC 60512-2-719 specifies the test method for measuring contact resistance using low-level test currents. The standard provides detailed procedures for preparing the specimens, setting up the test equipment, and performing the actual test. It also outlines the requirements for the measurement equipment, such as suitable current sources, voltage measurement devices, and data acquisition systems. By following these standardized test methods and procedures, manufacturers can ensure reliable and comparable results across different types of connectors and electronic equipment.
Criteria and Acceptance Limits
IEC 60512-2-719 defines the acceptance limits for contact resistance based on the type of connector and its intended application. The standard specifies maximum permissible contact resistance values, which vary depending on factors such as the current carrying capacity and the type of signal being transmitted. Manufacturers must ensure that the measured contact resistance falls within these acceptance limits to meet the requirements of the standard. Any deviations from the specified limits should be analyzed and addressed to maintain the quality and reliability of the connectors.
Contact: Nina She
Phone: +86-13751010017
E-mail: info@iec-equipment.com
Add: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China