IK & IP Testing for Lighting Products
Ratings that demonstrate the degree of Impact Protection (IK) and Ingress Protection (IP) are critical for street, roadway and other lighting products. IP ratings are required per IEC/EN 60598-2-3 for all roadway and street applications. IK ratings are required in specific applications when high impact glass provides protection for the enclosed lamp.
Standards
IEC 62262 specifies the way enclosures should be tested for IK ratings which are defined as the level of protection the enclosures provided against external mechanical impacts. IEC 60598-1 (IEC 60529) specifies the test method used to classify and rate the degree of protection an enclosure provides against intrusion of various sized solid objects from fingers and hands to fine dust and the protection against water intrusion from falling drops to a high pressure water jet. IEC 60598-2-3 is the International Standard for Luminaires for Road and Street Lighting.
UL offers complete testing and certification services for street and roadway luminaires to IEC 60598-2-3
IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by electrical enclosures (including luminaires) against external mechanical impacts. The IK rating scale identifies the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating.
Degrees if protection again external mechanical impacts
IK00
IK02
IK03
IK05
IK06
IK07
IK08
IK09
IK10
Non-protected
0.2J
0.35J
0.5J
0.7J
1J
2J
5J
10J
20J
IP ratings are defined as IPXX where the first X indicates the degree of protection against solid objects and the second X indicates the degrees of protection against water. A luminaire or lighting component with a rating of IP66 is dust-tight and protected against powerful water jets as described in IEC 60598-1 (IEC 60529).]
Degrees if protection again solid objects |
|
IP0X |
Non-protected |
IP1X |
50mm diameter and greater |
IP2X |
12.55mm diameter and greater |
IP3X |
2.5mm diameter and greater |
IP4X |
1.0mm diameter and greater |
IP5X |
Dust-protected |
IP6X |
Dust-tight |
Degrees if protection again water |
|
IP0X |
Non-protected |
IP1X |
Vertically falling water drops |
IP2X |
Vertically falling water drops with enclosure tilted |
IP3X |
Spraying water |
IP4X |
Splashing water |
IP5X |
Water jets |
IP6X |
Powerful water jets |
IP7X |
Temporary immersion |
IP8X |
Continuous immersion |